Non-contact IV tester

Quantum Efficiency Tester
Accurate EQE, IQE and spectral response measurements—from localized spots to full cells.
The MNPVQE-1800T PRO is designed for photovoltaic research and production, providing accurate measurements of solar cell spectral response, external quantum efficiency (EQE/IPCE) and internal quantum efficiency (IQE). The MNPVQE-1800T PRO supports a wide range of photovoltaic devices, including crystalline silicon, multicrystalline silicon, amorphous silicon, microcrystalline silicon, CdTe, CIGS, CIS, Ge, dye-sensitized, organic/polymer, tandem, multijunction, quantum-well, quantum-dot, chalcogenide and perovskite solar cells.PL/EL Integrated System
PV-Reflectumeter
3D Confocal Microscope
In-Line Four Point Probe Tester
Four Point Probe Tester
In-Line Thin Film Thickness Tester
Raman Spectrometer
FTIR Spectrometer
Spectrophotometer
Automatic Spectroscopic Ellipsometer
Contact Resistance Tester
Ultra depth of field 3D microscope
Auto Visual Tester
VMM PV Vision Measuring Machine
Solar Cell Horizontal Tensile Tester
Steady State Solar Simulator for Solar Cell
Solar Cell UV Aging Test Chamber
Solar Cell Comprehensive Tensile Tester
Visual Inspection Tester
Wet Leakage Current Tester
PV Module EL Tester
PV Module UV Preconditioning Chamber
Steady State Solar Simulator for PV Module
Current Continuous Monitor
Potential Induced Degradation Test
Bypass Diode Tester
LeTID Test System
Reverse Current Overload Tester
Impulse Voltage Tester
Hipot Insulation Tester
Ground Continuity Tester
Hipot Insulation Ground Tester
Damp Heat Test Chamber
Humidity Freeze Test
Thermal Cycle Test Chamber
Dynamic Mechanical Load Tester
Static Mechanical Load Tester
Hail Impact Tester
Robustness of Termination Tester
Module Breakage Tester
Cut Susceptibility Tester
Peel Shear Strength Tester
Universal Testing Machine (Single-arm)
Universal Testing Machine (Double-arm)
Glass Transmittance Tester
Acetic Acid Test Chamber
EVA Degree of Crosslinking Test System
Junction Box Comprehensive Tester
Drop ball tester
Semi-automatic scanning four-probe tester
Stylus Profilometer
Maximum Power Point Tracker
Perovskite Glass Transmittance Tester
Perovskite P1 Laser Scribing Multifunctional Testing Machine
Perovskite Online PL Tester
Perovskite Online Sheet Resistance Tester
Online Perovskite Film Thickness Tester
Perovskite Process Inspection Workstation
Portable EL Tester
Portable Thermal Imaging Tester
Solar Module Multi-Channel Testing System
PV Inverter Power Quality Tester
IV Tester
IVEL Cell Sorting Machine
Pure-Iodide Wide-Bandgap Perovskite Solar Cells: 22.1% Certified Efficiency and 8,140-Hour Projected T80 Lifetime
Date : 17 November 2026Views : 50
Silicon/perovskite tandem solar cells are a major direction for next-generation photovoltaics. Their top cells commonly use mixed-halide wide-bandgap perovskites, but halide segregation remains a persistent challenge for operational lifetime. The Millennial Solar perovskite maximum power point tracking (MPPT) testing system uses a Class 3A+ LED solar simulator as an aging light source and supports temperature and atmospheric control for long-term stability testing.
This study used DMA⁺-stabilized pure-iodide Cs₀.₃DMA₀.₂MA₀.₅PbI₃ perovskite (bandgap approximately 1.68 eV) as the absorber. Bilayer EDAI₂/PDI interfacial passivation increased Voc from 1.12 V to 1.25 V and enabled a certified efficiency of 22.1%. Compared with mixed-halide compositions, the pure-iodide material maintained stable emission yield under illumination and thermal aging, with much smaller changes in ionic losses and ion density. Under combined light and heat stress at 85°C (ISOS-L-2), its linearly extrapolated T80 lifetime reached 8,140 hours. The source article describes this as a first for this class of wide-bandgap perovskites and as 5–8 times the minimum accelerated-test benchmark associated with a 25-year operating lifetime.
The devices employed a p-i-n architecture: ITO/NiOₓ/4PADCB self-assembled monolayer/perovskite/C₆₀/BCP/Ag. The perovskite precursor used DMF/NMP solvents with MACl, PMAI, and Pb(SCN)₂ additives. Interfacial passivation was applied at the perovskite/C₆₀ interface by sequential spin-coating of EDAI₂ and PDI. Stability testing included continuous one-sun MPPT tracking, dark thermal aging at 85°C, and combined one-sun illumination and 85°C aging. Ionic behavior was characterized using fast hysteresis (FH) measurements at scan rates of 100–1,000 V/s, bias-assisted charge extraction (BACE), capacitance–frequency (C–f) analysis, and time-of-flight secondary ion mass spectrometry (TOF-SIMS) depth profiling. Nonradiative recombination losses were evaluated by photoluminescence quantum yield (PLQY) and quasi-Fermi-level splitting (QFLS). Crystal structure was analyzed by conventional XRD and grazing-incidence XRD (GI-XRD) at an incidence angle of 0.5°.

Device architecture, SEM morphology, Voc comparison for different passivation layers, PLQY/QFLS–Voc analysis, PCE distribution, J–V curves, and EQE spectra.
Both films exhibited dense polycrystalline morphologies. The Br–I grains measured 200–300 nm, while pure-iodide grains were approximately 180 nm, consistent with nucleation-dominated crystallization in the DMF/NMP solvent system. Bilayer passivation increased Voc by approximately 130 mV in both compositions. The pure-iodide cell achieved a maximum PCE of 22.4%, a certified PCE of 22.1%, and a fill factor of 83.4%. Despite having the same nominal bandgap, the pure-iodide device showed a higher EQE-integrated Jsc (21.14 mA/cm²) than the mixed-halide device (20.33 mA/cm²).

Evolution of PL spectra under illumination; UV–visible absorption spectra before and after aging; conventional XRD; and GI-XRD at an incidence angle of 0.5°.
Under illumination, the 77:23 Br–I film exhibited a redshift in PL, degraded absorption, and an additional GI-XRD diffraction peak at approximately 13.7°, confirming halide segregation. In contrast, the pure-iodide film showed no change in its PL spectrum over 24 hours, while the XRD peak shape and position remained unchanged after aging. The main pure-iodide diffraction peak occurred at a lower angle, corresponding to a larger unit-cell volume and enhanced Pb–I–Pb octahedral tilting.

MPPT light-stability tracking; PCE and Jsc at different scan rates; differences between fast- and slow-scan PCE; and evolution of the ionic-loss fraction (1 − Ψs/Ψf) during aging.
During MPPT testing, the Br–I device retained only 40% of its initial PCE after 1,000 hours, whereas the pure-iodide device retained more than 95% after 2,000 hours. FH measurements showed that ionic losses in the Br–I device increased from 2.6% to 9.5%, while those in the pure-iodide device remained at approximately 2%.

BACE measurements, C–f response, TOF-SIMS depth profiles, and comparison of QFLS in partial stacks with device Voc.
BACE measurements showed that ionic charge density in the Br–I device more than tripled after eight hours, while the pure-iodide device exhibited an increase of only about 10%. The Br–I device developed a pronounced low-frequency capacitance increase in C–f measurements, whereas the pure-iodide device showed little change. TOF-SIMS confirmed halide redistribution toward the surface and electron transport layer (ETL) interface in Br–I devices, but not in pure-iodide devices. QFLS analysis indicated increasing interfacial nonradiative recombination in Br–I devices, with a widening QFLS–Voc gap over time. The pure-iodide device showed a modest decline of approximately 10 mV, suggesting a limited contribution from deep-level defects.

Dark thermal-storage stability at 85°C; BACE ionic charge density before and after 85°C aging; ionic losses under one-sun illumination at 85°C; MPPT photothermal stability curves at 85°C; and comparison of reported wide-bandgap perovskite T80 lifetimes versus PCE.
After 1,000 hours of dark aging at 85°C, the pure-iodide device lost approximately 3% of its efficiency, compared with approximately 30% for the Br–I device. Voc remained stable in both cases, and the losses mainly arose from fill-factor degradation. Under combined 85°C and illumination stress, the Br–I device lost more than 70% of its efficiency within 600 hours, while the pure-iodide device retained 95.7% after 1,750 hours. Linear extrapolation yielded a T80 lifetime of 8,140 hours, exceeding the reported 1,686 hours for thermally evaporated Cs₀.₄₅FA₀.₅₅Pb(Br₀.₁₅I₀.₈₅)₃ and approximately 5,000 hours for an inorganic perovskite. It also exceeded the cited accelerated-test benchmark of 1,000–1,500 hours associated with a 25-year operating lifetime. XRD and ab initio molecular dynamics simulations indicated that DMA⁺ expanded the unit-cell volume and increased the activation energy for ion migration. Steric hindrance suppressed halide migration and MA⁺ volatilization, helping explain the unexpectedly strong thermal stability of this MA-containing pure-iodide composition.
Through bilayer passivation, the pure-iodide wide-bandgap perovskite achieved a Voc of 1.25 V and a certified efficiency of 22.1%. BACE, C–f, and TOF-SIMS results linked its enhanced stability to strongly suppressed ionic losses and the absence of observed halide segregation. The projected T80 lifetime under 85°C photothermal stress reached 8,140 hours, described in the source as a leading result among solution-processed wide-bandgap perovskites. DMA⁺-assisted A-site engineering restricted ion migration and strengthened structural integrity, offering a potential route toward more stable silicon/perovskite tandem solar cells. Further optimization could investigate replacing MA⁺ with FA⁺.
Q1: What efficiency did the pure-iodide wide-bandgap perovskite cell achieve?
The cell achieved a certified power conversion efficiency of 22.1%, a maximum measured efficiency of 22.4%, and a fill factor of 83.4%.
Q2: How did pure-iodide devices compare with mixed-halide devices during MPPT testing?The pure-iodide devices retained more than 95% of their initial efficiency after 2,000 hours, while the Br–I devices retained 40% after 1,000 hours.
Q3: What does the reported 8,140-hour T80 lifetime represent?It is a linearly extrapolated time to 80% of initial efficiency under combined one-sun illumination and 85°C stress, based on the reported photothermal stability measurements.

E-mail: market@millennialsolar.com
The Millennial Solar perovskite MPPT testing system uses a Class 3A+ LED solar simulator as its aging light source. Compared with the previous generation, the spectral range has been extended to 300–1700 nm (AM0), the spectral classification reaches AAA (AM0), and 24 channels can be adjusted independently. The system supports research on perovskite solar cells, space photovoltaics, and tandem cells (2T/3T/4T).
▶ Light source classification: AAA (AM0), with a spectral range of 300–1700 nm for space photovoltaic testing.
▶ Independent spectral control: 24 adjustable channels (AM0) to match the subcell bandgaps of triple- and quadruple-junction tandem cells.
▶ Large-sample fixture: Supports tandem cells up to 210 × 105 mm, using front- and rear-side gold-wire pressure contacts for electrode connection.
▶ Environmental control: Semiconductor-based temperature control from 15°C to 100°C, with testing also available under a moisture- and oxygen-free nitrogen atmosphere.
The Millennial Solar perovskite MPPT testing system serves as both a performance-verification tool and a testing platform for research on perovskite and tandem solar cells.
Original Research Reference: Photothermal-stable pure-iodide wide-bandgap perovskite solar cells with suppressed ionic losses.
Related Products
































































